Arnoldstraße 19 • 47906 Kempen, Germany +49 2152 8955-0 vertrieb@alders.de
Operation time indicators
Elapsed Time Indicator AC Series
- FEATURES
Rugged design
Hermetically sealed - MECHANICAL SPECIFICATIONS
Case: Copper nickel or brass, with durable black finish.
E and F mounts are nickel-plated case with black face.
Max. case length: Short version: 1.094 in.
Long version: 2.082 in.
Flange: Brass
Terminals: Solder hook
Weight: 0.4 ounces maximum without mount
0.6 ounces maximum with C flange
Numerals: .035″ wide, .078″ high. Hour digits are white on
black. Tenths are red on white. - ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range: -65 to +125°C
Shock: MIL-STD-202, Method 213, Condition I
Vibration: MIL-STD-202, Method 204, Condition D - ELECTRICAL SPECIFICATIONS
Meters meet or exceed applicable requirements of MIL-M-7793
M7793/3, /4, /6, /8, /9, /10 (if QPL’d) MS27650 & 27651.
Special ratings and configurations are also available.
Transient Protection: As applicable, 180 VRMS up to
0.15 seconds
Dielectric: 350 VRMS @ 80,000 ft., 600 VRMS @ sea level
Insulation Resistance: MIL-STD-202, Method 302, Condition B
Accuracy: 0.1% over temperature/voltage range - Power Consumption:
D21 & D25= .015 Watts
D91, D92, & D95 = .3 Watts
Reading Allowed at time of Shipments: Meters can be
delivered with +/- 1 hour upon delivery per MIL-DTL-7793
ELAPSED TIME INDICATORS DC SERIES : SUBMINIATURE
- FEATURES
Rugged design
Hermetically sealed
Low voltage models available - MECHANICAL SPECIFICATIONS
Case: Copper-nickel or brass, with durable black finish.
E and F mounts are nickel-plated case with black face.
Max. case length: Short version: 1.094 in.
Long version: 2.082 in.
Flange: Brass
Terminals: Solder hook
Weight: 0.4 ounces maximum without mount
0.6 ounces maximum with C flange
Numerals: .035″ wide, .078″ high. Hour digits are white on
black. Tenths are red on white. - ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range: -65 to +125°C
Shock: MIL-STD-202, Method 213, Condition I
Vibration: MIL-STD-202, Method 204, Condition D - ELECTRICAL SPECIFICATIONS
Meters meet or exceed applicable requirements of MIL-DTL-7793
M7793/1, /2, /5 and MS21341 A & B. Special ratings and
configurations are also available.
Transient Protection: MIL-STD-704A, 80 & 600 V
(Models 16 & D16)
Ripple Protection: MIL-STD-704A, para. 5.2.2 to 5.2.2.1 & Fig. 7
(Models 16 & D16)
Dielectric: 350 VRMS @ 80,000 ft., 600 VRMS @ sea level
Insulation Resistance: MIL-STD-202, Method 302, Condition B
Accuracy: 0.1% over temperature/voltage range
Power Consumption: D16 & 16 = .085 Watts, D46=.010 Watts
Reading Allowed at time of Shipments: Meters can be
delivered with +/- 1 hour upon delivery per MIL-DTL-7793