For the measurement of gas in the ambient air, we rely on gas sensors from our premium partner FES Sensor Technology. As an expert in hydrogen sensor technology with many years of experience, FES offers innovative calibrated hydrogen sensors that are insensitive to siloxanes. Typical applications of our hydrogen sensors are areas in which hydrogen is produced, stored, transported and used. FES offers hydrogen sensors for industrial leak detection, fuel cell, laboratory, automotive and many other applications. The gas sensors are characterized by the following properties, among others:

  • high robustness and long service life
  • absolutely maintenance-free
  • high sensitivity and selectivity to hydrogen up to the lower explosive limit (LEL)
  • insensitive to typical catalyst poisons such as volatile siloxanes and carbon monoxide

FES Sensor Technology Hydrogen-Sensor H2-CNI I2C-E-ULTD

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • Extended temperature range from -40 °C to +120 °C
  • Ultralow thermal drift
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output up to 100 % LEL
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • On-board digital temperature sensor and EEPROM with I2C®bus connectivity

FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 4-20mA-I & H2-CNI 4-20mA-I ULTD

  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Negligible sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • Negligible humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range -40 °C to +80 °C
  • Linear output up to 100 % LEL
  • Available with ultra-low thermal drift (ULTD) and test protocol
  • 4-20 mA current-loop transmitter with reverse voltage operation and over-voltage surge protection
  • Supply voltage with reversed bias protection

FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 0V-I & H2-CNI 0V-I ULTD

  • Detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range from -40 to +80 °C
  • High mechanical stability
  • Linear output up to 100 % LEL
  • Available with ultra-low thermal drift (ULTD) and test protocol
  • On-board instrumentation amplifier and voltage output
  • Supply voltage with reversed bias protection
FES Sensor Technology Wasserstoffsensor Hydrogen-Sensor H2-CNI 1V Alders

FES Sensor Technology Hydrogen-Sensor H2-CNI 1V

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  •  No humidity-induced base line drift
  •  Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range from -10 to +50 °C (optional: other temperature ranges)
  •  Linear output up to 100 % LEL
  •  On-board sensor electronics
  •  Zero-signal voltage adjusted to 1 V for operation with 4-20 mA interface electronics
FES Sensor Technology Wasserstoffsensor Hydrogen-Sensor H2-CNI 1V Alders

FES Sensor Technology Hydrogen-Sensor H2-CNI 0V

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range from -10 to +50 °C (optional: other temperature ranges)
  • Linear output up to 100 % LEL
  • On-board sensor electronics
FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 12C alders

FES Sensor Technology Hydrogen-Sensor H2-CNI I2C

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range from -40 °C to +90 °C
  • Linear output up to 100 % LEL
  • On-board digital temperature sensor and EEPROM with I2C®bus connectivity

FES Sensor Technology Hydrogen-Sensor H2-CNI with 4-20 mA Transmitter

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range +10 to +30 °C (optional: other temperature ranges)
  • Linear output up to 100 % LEL
  • On-board sensor electronics
  • 4-20 mA current-loop transmitter with reverse voltage operation and overvoltage surge protection
FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 12C alders

FES Sensor Technology Hydrogen-Sensor H2-CCT 12C

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity‐induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output up to 100 % LEL
  • On‐chip Pt1000 element and heater
  • Industrial temperature range from ‐40 °C to +85 °C