FES Sensor Technology Hydrogen-Sensor H2-TCD 4-20mA

H2-TCD 4-20mA is a hydrogen sensor for applications without oxygen and is based on a thermal conductivity operation principle. The sensor contains a Si-based heated transducer, fabricated by anisotropic etching, and on-board electronics, including the voltage sources for the transducer, a non-volatile digital rheostat for adjusting the Wheatstone bridge with the transducer, an instrumentation amplifier, and a secure 4-20 mA current interface. It is designed for use in a variety of applications which require an accurate hydrogen determination in nitrogen or other non-oxygen-containing atmospheres.

Description

  • Accurate detection of hydrogen levels in air and nitrogen up to 15% vol-%
  • Fast response and recovery times
  • Applicable in relative humidity (rh) between 0% to 100%
  • Temperature range -20°C to +85°C
  • Linear output up to 5% vol-%
  • Very low power consumption < 10 mW
  • 4-20 mA current-loop transmitter with reverse voltage operation and over-voltage surge protection
  • Supply voltage with reversed bias protection

Documents & downloads

Specification Sheet H2-CNI I2C Rev. 1.0

Accessories

Christian Kallen
Christian Kallen
Vertrieb
cka@alders.de +49 2152 8955-230
print